MR-401RP

The MR-401RP Addressable Fire Alarm Control Panel is a 3 (SLC) loops addressable multi-zoned panel compatible with the new MRI-4000 Series.

The MR-401 Addressable Fire Alarm Control Panel is a 3 (SLC) loops addressable multi-zoned panel compatible with the new MRI-4000 Series.

4 Reasons to choose the MR-401RP Addressable Fire Alarm Control Panel:

  1. The panel is ideal for small to medium jobs. It is easy to install and configure.
  2. The MR-401RP is shipped pre-assembled. It comes with the mainboard, power supply, transformer, main display, black backbox, and a red door enclosure.
  3. The panel is compatible with the new MRI-4000 Series. It comes with one addressable (SLC) loop and it can have up to 3 loops, with a maximum of 240 MRI-4000 devices per loop. Connect the ALC-480 Dual Loop Adder to the panel to have the extra 2 (SLC) MRI-4000 devices compatible loops. The ALC-480 is sold separately.
  4. The MR-401RP is equipped with a built-in dialer. The dialer provides a means to communicate panel status to the remote central monitoring station using two dedicated phone lines.

Secutron’s MR-401RP Addressable Fire Alarm Control Panel provides the following:

  • Main Board, Power Supply and Backbox.
  • Flexible zone and group configuration options.
  • 3500 Main Display with 4 x 20 LCD display.
  • Class A (DCLA), Class X (DCLC), or Class B (DCLB) analog loop(s).
  • Four Power Limited Class B, Class A NAC circuits (max 1.5 Amps each – 6.0 Amps total).
  • Up to 3 MRI-4000 Compatible (SLC) loops with a maximum of 720 devices, 240 per loop.
  • Dedicated common alarm, supervisory, trouble, and auxiliary alarm relays.
  • Additional RAX-1048TZDS Display Adder Module can be added to provide 96 annunciation points per Adder.
  • Additional outputs include connections for a remote trouble indicator MR-2300T, Reverse Polarity Module MR-2300-PR, an RS-485 bus for connection of up to seven RAX-LCD-LITE, RAM-3500-LCDs, SRM-312s and RA-1000 Series annunciators.
  • Auxiliary power is available in the form of 24V FWR unfiltered and unsupervised, 24VDC filtered and regulated, and resettable auxiliary power supply.
  • Built-in POTs dialer which allows for the reporting of events to a monitoring facility.

 

ulSecutron FM Approved

Support Tools & Resources

Tools

File Size Version Notes/References
MR-400 Series Configurator 47 MB 2.1.3 LT-6772 Password Setup Instructions for MR-400 Series Password Configurator
MR-400RP Series Firmware 1.1 MB 2.1.10 Firmware for Password Encryption (SO108_V2.1.10)

Training

YouTube Resources LMS Portal Notes/References
MR-401 Overview
MR-401 Details – Tech 1
MR-401 Programming
MR-4000 Addressable Devices

Welcome to Secutron

Please choose your region.

Welcome to Secutron

Please choose your region.